Crawl Space Moisture Control

Written by  The U.S. Department of Energy's Office of EERE

To effectively insulate your crawl space for energy efficiency and to create a comfortable home, you need to properly control moisture in your crawl space.

Crawl Space Moisture Control

 

 

 

 

 

Topic Summary

A crawlspace is susceptible to moisture and deterioration problems because of contact with the earth. The best approaches for preventing these problems will depend on your local climate and the style of your home's construction. However, the following general guidelines for creating a water-managed foundation system apply to most crawl space designs:

  1. Keep all untreated wood materials away from the earth.
  2. Provide rain drainage, such as gutters, to conduct rainwater away from the house.
  3. Slope the earth away from the house for at least 5 feet at a minimum 5% grade (3 inches in 5 feet). Establish drainage swales to direct rainwater around the house.
  4. Add a sill gasket to provide air sealing.
  5. Install a protective membrane, such as an EPDM-type membrane, to serve as a capillary break that reduces wicking of water from the masonry wall. This membrane, in addition to metal flashing, can serve as a termite shield.
  6. Damp-proof the below-grade portion of the foundation wall to prevent the wall from absorbing ground moisture by capillary action.
  7. Install drainage plane material or gravel against the foundation wall to relieve hydrostatic pressure and channel water to the foundation drain.
  8. Provide a foundation drainage system at the bottom of the footing, not on top, when the foundation floor (interior grade) is below the exterior grade. Surround a perforated 4-inch drain pipe with gravel, and cover them with filter fabric.
  9. Install 6-mil polethylene vapor diffusion barrier across the crawl space floor to prevent soil moisture from migrating into the crawl space. Overlap and tape all seams by 12 inches. Seal the polyethylene 6 inches up the crawl space walls. As an option, pour two inches (51mm) of concrete over this to protect the polyethylene from damage.

Article source: The U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy (EERE). For the most up-to-date information please visit the EERE website.